Sign In | Join Free | My burrillandco.com
Home > Battery Testing Equipment >

AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery

    Buy cheap AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery from wholesalers
     
    Buy cheap AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery from wholesalers
    • Buy cheap AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery from wholesalers
    • Buy cheap AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery from wholesalers

    AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery

    Ask Lasest Price
    Brand Name : GSKA
    Model Number : Battery Short-Circuit Test Chamber
    Certification : CE SGS ROHS UL CE
    Price : Negotiate
    Payment Terms : L/C, T/T
    Supply Ability : 1000 Set / Sets per Month
    Delivery Time : 10-60days after confirmed payment or by contract stipulation
    • Product Details
    • Company Profile

    AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery

    AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery


    Product use:


    The battery pack short-circuit equipment is mainly used for the safety verification test of power battery cells, monomers, modules, PACK-level battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, cells, modules, and PACK-level battery packs during use, transportation and storage to evaluate the safety performance of batteries. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality

    Product manual:


    1. Application of battery pack short circuit equipment: It is mainly used for the safety verification test of power battery cells, monomers, modules, PACK and other battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, monomers, modules and PACK battery packs during use, transportation and storage to evaluate the safety performance of the battery. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality.


    2. The battery pack short-circuit equipment is composed of a short-circuit control box, a vacuum arc extinguishing device, a short-circuit terminal wiring, a data acquisition system and a computer for data analysis.

    Overview of battery pack short-circuit equipment design:


    The short-circuit equipment is designed based on the requirements of various battery short-circuit test standards, that is, it meets CB31467.31CB31485UU25801SAE J24641SAEJ2929UN38.3ECER100IEC6213UL1642 Qc / T 743 and "863i Plan" Energy-Saving and New Energy Vehicle Major Projects - 2008 EV Lithium-ion Power Battery Performance Test Specifications and other standards; short-circuit devices must meet the internal resistance range according to the standard <5m or >5m2&<10m or >10m2&<20m or >40m&<50m or >80m&100m2 to obtain the maximum short-circuit current of the test; the circuit design of the short-circuit device can also withstand the impact of a large current of 16000A, so we choose industrial grade mechanical suction

    fulfill the standard:


    1. CB31467.3 "Lithium-ion power battery packs and systems for electric vehicles No. 3: Safety requirements and test methods"


    2.CB/T 31485-2015 "Safety Requirements and Test Methods for Power Batteries for Electric Vehicles"


    QC/ T 743-2006 "Lithium-ion batteries for electric vehicles"


    CB/T 18332-2015 "Zinc Air Batteries for Electric Vehicles"


    5. Ji 2580-2013 "Electric Vehicle Battery Safety Standards"


    6. SAND99-0497 "American Automotive Power Battery Test Standard"


    7. SAE J2464 "Electric and Hybrid Electric Vehicle Charging and Energy Storage Safety and Abuse Test"


    8. SAE J2929-2013 "Safety Standard for Electric and Hybrid Vehicle Propulsion Battery Systems." Lithium-based rechargeable battery" and

    other test standards



    technical parameter


    Impulse voltage

    AC 1kv/1.2-50us (peak) lmin

    Action characteristics

    Cold state pull-in voltage 66%Us

    Cold release voltage bucket 30%Us,*5%Us

    Action time

    Pull-in time/release time: 20ms

    Maximum operating current duration

    ≥10ms5.5.

    Voltage acquisition range

    0-1000v

    Voltage resolution

    0.01v

    Voltage measurement accuracy

    ±0.5% (full scale)

    Voltage set channel

    Standard 1 channel, isolated between channels, can support expansion

    Rated test current

    ≥10000A

    Maximum operating current

    ≥15000A

    Maximum pulse current

    ≥16000A

    Current acquisition range

    0-15000A

    Current measurement accuracy

    1000A-15000A, the accuracy is ±0.5%

    Current resolution

    0.1A

    Current acquisition channel

    Standard 1 channel, isolated between channels, can support expansion

    Temperature acquisition range

    -200-1350ºC

    Temperature acquisition accuracy

    ≤±1.5ºC

    temperature acquisition channel

    Standard 12 channels, isolated between channels, can support expansion

    Data collection frequency

    7.19.1.10mslhr, 19 kinds can be set (if the test channel is more than
    15 channels at the same time, the acquisition frequency can be set as
    20ms-1hr)

    7.19.2. Due to the high frequency of data collection, the data read and
    recorded by the device in real time can be consistent with the actual data

    Runtime recording accuracy

    ≤±0.1% (full scale)

    Test Data

    The voltage/current/temperature data is displayed and recorded on the control
    software in real time, and the voltage/current/temperature/time curve is
    automatically drawn

    way to control

    Using remote touch screen control + remote control + computer (for data
    analysis and video monitoring)

    short circuit

    Mechanical pull-in (contactor pneumatic pull-in, synchronous forced disconnection
    device when disconnected) + vacuum arc extinguishing device

    Short circuit cut-off condition

    Short circuit can be stopped by setting voltage and time parameters

    Device circuit resistance

    <5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, the corresponding
    rated test currents satisfy 10000A, 10000A, 5000A, 5000A, 3000A, respectively.
    It includes the electrical components inside and outside the device + the internal
    resistance of the cable + the internal resistance of the fixture.

    Short circuit terminal wiring

    <5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, 1 pair each,
    The length of the wrong line is not less than 6 meters, and there are 5 pairs in total.
    The cross-sectional area of the soft copper wire at the output end of the device is not
    less than 2000mm²

    Short circuit internal resistance switching mode

    Manual switching, one end of the short-circuit terminal wire is a through nose,
    which can be fixed by bolts with the screw holes of the contactor, and the other
    end is a battery clamp with copper terminals, which can be directly clamped on
    the positive and negative poles of the battery to replace It can be replaced by
    simply removing the fixing bolts

    Short circuit test response time
    (short circuit start to close to fully closed)

    ≤10ms

    Mechanical life

    300,000 times

    Electrical life

    50,000 times

    Remote control distance

    No solid barrier 10m

    short circuit time

    0-9999H59M59S can be set



    Customer Support Services:


    Ø Installation


    Ø Training (Training customer employees)


    Ø Preventative maintenance


    Ø Replacement parts


    Ø Assistance via phone or internet


    Ø On-site diagnosis and repair/online diagnosis and repair


    Quality AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)